We use cookies to personalise content and ads, to provide social media features and to analyse our traffic. We also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services. You consent to our cookies if you continue to use our website.

Saving settings for instruments when file transfer is switched on

Enabling the file transfer (AUTO) function causes instruments to be configured with model-specific save settings as follows:

ModelAutomatic save settingsFile save timing
PQ3100•Recording interval: 1 sec. to 5 min.
•Recording start method: Repeat, 2000-01-01
•Recording stop method: Repeat, 2079-12-31
•Recording time period: 00:00 to 24:00
•Delete file after FTP transfer: ON
•Folder/file name setting: Automatic
•When an event occurs as defined by conditions set with instrument
•Daily at 00:00
•When measurement stops
•When the time-axis file reaches 20 MB
PQ3198•Actual time control: Exact time
•Repeat recording: 1 day
•Start time: 00:00; end time: 00:00
•Repeat count: Unlimited (configurable only in GENNECT)
•Delete file after FTP transfer: ON
•Folder/file name setting: Automatic
•Daily at 00:00
•When measurement stops (Files cannot be sent while an event is occurring.)
PW3360
PW3365
•Recording measurement start method: Repeat
•Recording repeat interval: 2000-01-01 to 2079-12-31
•Recording repeat time: 00:00 to 24:00
•Delete file after FTP transfer: ON
•When folder division is OFF, change it to DAY.
•Save file/folder name: AUTO-NAME
•When an event occurs as defined by conditions set with instrument
•Daily at 00:00
•When measurement stops
•When the time-axis file reaches 20 MB
PW8001•Auto-save operation: ON
•Delete files after upload: ON
•When measurement stops
•When [DATA RESET]
•When the file size reaches 500MB
•When waveform is saved
•When saving a setting file
•When saving a screen copy (*Manually saved measurement data is not compatible with File Transfer (AUTO)).
LR8400
LR8401
LR8402
LR8410
LR8416
•Recording time setting: Continuous recording
•Automatic save setting: Waveform or CSV (numerical files not supported)
•Delete save: ON
•Segmented save: ON*/regular
*Changes as follows:
 Segmented save: Regular
 Segment time: 1 day
 Reference time: 00:00
•When the time set as the segmented save time is reached
•When measurement stops
LR8450, LR8450-01•Recording time setting: Continuous recording
•Automatic save setting: Waveform or CSV (numerical files not supported)
•Delete save: ON
•Delete sent file: ON
•Segmented save: ON*
*Changes as follows:
 Segment time: 1day
 Reference time: Start time
•When the time set as the segmented save time is reached
•When measurement stops
MR6000•Real-time saving: OFF
•Delete save: ON*
*Changes as follows when the automatic save setting target is disabled:
 Waveforms save: ON
 Save type: Binary
 Save method: Delete
 File segments: 64MB
•Segmented save setting
 If 0 when setting is binary: Changes to 64.
 If 0 when setting is text: Changes to 1000000.
•Save filename: AUTO
•When measurement completes according to the instrument’s setting conditions using the automatic save function.
(Automatic transfer of files generated by real-time saving is not supported.)