Saving settings for instruments when file transfer is switched on
Enabling the file transfer (AUTO) function causes instruments to be configured with model-specific save settings as follows:
| Model | Automatic save settings | File save timing |
|---|---|---|
| PQ3100 | •Recording interval: 1 sec. to 5 min. •Recording start method: Repeat, 2000-01-01 •Recording stop method: Repeat, 2079-12-31 •Recording time period: 00:00 to 24:00 •Delete file after FTP transfer: ON •Folder/file name setting: Automatic | •When an event occurs as defined by conditions set with instrument •Daily at 00:00 •When measurement stops •When the time-axis file reaches 20 MB |
| PQ3198 | •Actual time control: Exact time •Repeat recording: 1 day •Start time: 00:00; end time: 00:00 •Repeat count: Unlimited (configurable only in GENNECT) •Delete file after FTP transfer: ON •Folder/file name setting: Automatic | •Daily at 00:00 •When measurement stops (Files cannot be sent while an event is occurring.) |
| PW3360 PW3365 | •Recording measurement start method: Repeat •Recording repeat interval: 2000-01-01 to 2079-12-31 •Recording repeat time: 00:00 to 24:00 •Delete file after FTP transfer: ON •When folder division is OFF, change it to DAY. •Save file/folder name: AUTO-NAME | •When an event occurs as defined by conditions set with instrument •Daily at 00:00 •When measurement stops •When the time-axis file reaches 20 MB |
| PW8001 | •Auto-save operation: ON •Delete files after upload: ON | •When measurement stops •When [DATA RESET] •When the file size reaches 500MB •When waveform is saved •When saving a setting file •When saving a screen copy (*Manually saved measurement data is not compatible with File Transfer (AUTO)). |
| LR8400 LR8401 LR8402 LR8410 LR8416 | •Recording time setting: Continuous recording •Automatic save setting: Waveform or CSV (numerical files not supported) •Delete save: ON •Segmented save: ON*/regular *Changes as follows: Segmented save: Regular Segment time: 1 day Reference time: 00:00 | •When the time set as the segmented save time is reached •When measurement stops |
| LR8450, LR8450-01 | •Recording time setting: Continuous recording •Automatic save setting: Waveform or CSV (numerical files not supported) •Delete save: ON •Delete sent file: ON •Segmented save: ON* *Changes as follows: Segment time: 1day Reference time: Start time | •When the time set as the segmented save time is reached •When measurement stops |
| MR6000 | •Real-time saving: OFF •Delete save: ON* *Changes as follows when the automatic save setting target is disabled: Waveforms save: ON Save type: Binary Save method: Delete File segments: 64MB •Segmented save setting If 0 when setting is binary: Changes to 64. If 0 when setting is text: Changes to 1000000. •Save filename: AUTO | •When measurement completes according to the instrument’s setting conditions using the automatic save function. (Automatic transfer of files generated by real-time saving is not supported.) |