We use cookies to personalise content and ads, to provide social media features and to analyse our traffic. We also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services. You consent to our cookies if you continue to use our website.

Models that support event recording and associated precautions

・When the "Maximum number of events that can be saved" has been recorded, the measurement will stop and no further events will be recorded.
・It may not be possible to detect events that last less than "Minimum detectable event duration" due to the inability to measure them accurately.

CM4001

・Supported functions: AC current measurement (ACA)
・Threshold setting: > (greater than)
・Maximum number of events that can be saved:99
・Minimum detectable event duration:200ms

CM4002,CM4003

・Supported functions: AC current measurement (ACA)
・Threshold setting: > (greater than)、<(less than)
・Maximum number of events that can be saved:999
・Minimum detectable event duration:200ms

FT6380-50

・Supported functions:AC current measurement(ACA)、Resistance measurement(Ω)
・Threshold setting: > (greater than)、<(less than)
・Maximum number of events that can be saved:25
・Minimum detectable event duration:1s

DT4261

・Supported functions:DC voltage measurement(DCV)、AC+DC voltage measurement(ACDCV)、DC voltage measurement(High V Probe Mode)(DCHV)、AC voltage measurement(ACV)、Frequency measurement(HzV)、Resistance measurement(Ω)、Electrostatic capacity measurement(F)、AC current measurement(with clamp sensor)(Clamp)、AC current measurement(ACA)、Frequency measurement(HzA)、DC current measurement(DCA)、AC+DC current measurement(ACDCA)
・Threshold setting: > (greater than)、<(less than)
・Maximum number of events that can be saved:99
・Minimum detectable event duration:200ms

CM4371-50,CM4373-50,CM4375-50

・Supported functions:DC voltage measurement(DCV)、DC voltage measurement(High V Probe Mode)(DCHV)、AC voltage measurement(ACV)、AC+DC voltage measurement(ACDCV)、Frequency measurement(HzV)、AC current measurement(ACA)、DC current measurement(DCA)、AC+DC current measurement(ACDCA)、Frequency measurement(HzA)、Resistance measurement(Ω)、Electrostatic capacity measurement(F)、Temperature measurement(℃/℉)
・Threshold setting: > (greater than)、<(less than)
・Maximum number of events that can be saved:99
・Minimum detectable event duration:400ms(Excluding some functions)※
※ Frequency、Electrostatic capacity:400ms ~ 4000ms(Depends on the measurement value)、Temperature:2000ms

CM4141-50

・Supported functions:DC voltage measurement(DCV)、DC voltage measurement(High V Probe Mode)(DCHV)、AC voltage measurement(ACV)、AC+DC voltage measurement(ACDCV)、Frequency measurement(HzV)、AC current measurement(ACA)、Frequency measurement(HzA)、Resistance measurement(Ω)、Electrostatic capacity measurement(F)、Temperature measurement(℃/℉)
・Threshold setting: > (greater than)、<(less than)
・Maximum number of events that can be saved:99
・Minimum detectable event duration:400ms(Excluding some functions)※
※Frequency、Electrostatic capacity:400ms ~ 4000ms(Depends on the measurement value)、Temperature:2000ms

CM3286-50

・Supported functions:AC current measurement(ACA)、AC voltage measurement(ACV)
・Threshold setting: > (greater than)、<(less than)
・Maximum number of events that can be saved:99
・Minimum detectable event duration:1s